XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Azimi S M, Rahimi H, Mirzabeigi A. Stabilization and control of power systems using under frequency load shedding due to spinning reverse. Journal of Iranian Association of Electrical and Electronics Engineers 2023; 20 (4) :163-172
URL: http://jiaeee.com/article-1-1485-en.html
Department of Electrical Engineering, Hamedan University of Technology
Abstract:   (1722 Views)
Frequency is one of the important components of the power system, which must be within the allowable range. With the occurrence of a severe disturbance, the governor system and rotating storage of power plants do not have the necessary ability to prevent a rapid drop in frequency. Under frequency load, shedding plans are one of the most important protection plans that are responsible for keeping the frequency within the permissible range in the event of severe disturbances. In this paper, while accurately calculating the active power required to keep the frequency constant, by affecting the spinning reverse energy of power systems in the load shedding stages, the minimum load is calculated to recover the frequency of the power system and the load is cut off. Designed for 4 stages of load shedding operations, in each stage, the amount of power deficit compensated by the rotating storage energy is checked and then the load is cut off. As an example, for a disturbance of 0.8 per unit, the amount of 0.3 per unit is compensated by the stored energy and only 0.5 per unit of load is disconnected from the network. In order to show the effectiveness of the proposed plan, the simulation results of using this plan for an island system have been compared with the simulation results of two common offloading plans. The results show that the proposed design shows more reliable and appropriate performance than the other two common designs. In this paper, while accurately calculating the active power required to keep the frequency constant, by affecting the spinning reverse energy of power systems in the load shedding stages, the minimum load is calculated to recover the frequency of the power system and the load is cut off. Designed for 4 stages of load shedding operations, in each stage, the amount of power deficit compensated by the rotating storage energy is checked and then the load is cut off. As an example, for a disturbance of 0.8 per unit, the amount of 0.3 per unit is compensated by the stored energy and only 0.5 per unit of load is disconnected from the network. In order to show the effectiveness of the proposed plan, the simulation results of using this plan for an island system have been compared with the simulation results of two common offloading plans. The results show that the proposed design is more reliable and appropriate performance than the other two common designs.

 
Full-Text [PDF 648 kb]   (1203 Downloads)    
Type of Article: Research | Subject: Power
Received: 2022/06/28 | Accepted: 2023/01/24 | Published: 2023/08/6

References
1. [1] A. Keyhani and A. Chatterjee, "Automatic generation control structure for smart power grids," IEEE Transactions on Smart Grid, vol. 3, no. 3, pp. 1310-1316, 2012. [DOI:10.1109/TSG.2012.2194794]
2. [2] K. Naidu, H. Mokhlis, and A. A. Bakar, "Multiobjective optimization using weighted sum artificial bee colony algorithm for load frequency control," International Journal of Electrical Power & Energy Systems, vol. 55, pp. 657-667, 2014. [DOI:10.1016/j.ijepes.2013.10.022]
3. [3] B. Delfino, S. Massucco, A. Morini, P. Scalera, and F. Silvestro, "Implementation and comparison of different under frequency load-shedding schemes," in 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No. 01CH37262), 2001, vol. 1, pp. 307-312: IEEE. [DOI:10.1109/PESS.2001.970031]
4. [4] م. ح. م. ف. امیری, "کنترل فرکانس-بار ریزشبکه دو ناحیه ای به وسیله کنترل کننده پیش بین مدل بهینه شده," 1 نشریه مهندسی برق و الکترونیک ایران، دوره: 19، شماره: , 1401.
5. [5] Q.-C. Zhong and T. Hornik, Control of power inverters in renewable energy and smart grid integration. John Wiley & Sons, 2012. [DOI:10.1002/9781118481806]
6. [6] M. Abedini, M. H. Moradi, and S. Hosseinian, "Optimal clustering of MGs based on droop controller for improving reliability using a hybrid of harmony search and genetic algorithms," ISA transactions, vol. 61, pp. 119-128, 2016. [DOI:10.1016/j.isatra.2015.12.012]
7. [7] J. C. Vasquez, J. M. Guerrero, J. Miret, M. Castilla, and L. G. De Vicuna, "Hierarchical control of intelligent microgrids," IEEE Industrial Electronics Magazine, vol. 4, no. 4, pp. 23-29, 2010. [DOI:10.1109/MIE.2010.938720]
8. [8] J. P. Lopes, C. Moreira, and A. Madureira, "Defining control strategies for microgrids islanded operation," IEEE Transactions on power systems, vol. 21, no. 2, pp. 916-924, 2006. [DOI:10.1109/TPWRS.2006.873018]
9. [9] F. Gao and M. R. Iravani, "A control strategy for a distributed generation unit in grid-connected and autonomous modes of operation," IEEE Transactions on power delivery, vol. 23, no. 2, pp. 850-859, 2008. [DOI:10.1109/TPWRD.2007.915950]
10. [10] Y. A.-R. I. Mohamed, H. H. Zeineldin, M. Salama, and R. Seethapathy, "Seamless formation and robust control of distributed generation microgrids via direct voltage control and optimized dynamic power sharing," IEEE Transactions on Power Electronics, vol. 27, no. 3, pp. 1283-1294, 2011. [DOI:10.1109/TPEL.2011.2164939]
11. [11] R. Majumder, B. Chaudhuri, A. Ghosh, R. Majumder, G. Ledwich, and F. Zare, "Improvement of stability and load sharing in an autonomous microgrid using supplementary droop control loop," IEEE transactions on power systems, vol. 25, no. 2, pp. 796-808, 2009. [DOI:10.1109/TPWRS.2009.2032049]
12. [12] U. Rudez and R. Mihalic, "Analysis of underfrequency load shedding using a frequency gradient," IEEE transactions on power delivery, vol. 26, no. 2, pp. 565-575, 2009. [DOI:10.1109/TPWRD.2009.2036356]
13. [13] U. Rudez and R. Mihalic, "A novel approach to underfrequency load shedding," Electric Power Systems Research, vol. 81, no. 2, pp. 636-643, 2011. [DOI:10.1016/j.epsr.2010.10.020]
14. [14] A. Ketabi and M. H. Fini, "An underfrequency load shedding scheme for islanded microgrids," International Journal of Electrical Power & Energy Systems, vol. 62, pp. 599-607, 2014. [DOI:10.1016/j.ijepes.2014.05.018]
15. [15] خ. م. م. دامون, "روشی غیرمتمرکز برای بازیابی شبکه توزیع فعال های مجاور در حضور ریزشبکه متصل به هم," نشریه مهندسی برق و الکترونیک ایران، دوره نوزدهم- شماره اول- بهار -1401صفحه 2 .
16. [16] P. M. Anderson and M. Mirheydar, "An adaptive method for setting underfrequency load shedding relays," IEEE Transactions on Power Systems, vol. 7, no. 2, pp. 647-655, 1992. [DOI:10.1109/59.141770]
17. [17] E. J. Thalassinakis and E. N. Dialynas, "A Monte-Carlo simulation method for setting the underfrequency load shedding relays and selecting the spinning reserve policy in autonomous power systems," IEEE Transactions on Power Systems, vol. 19, no. 4, pp. 2044-2052, 2004. [DOI:10.1109/TPWRS.2004.835674]
18. [18] L. Sigrist, I. Egido, and L. Rouco, "A method for the design of UFLS schemes of small isolated power systems," IEEE Transactions on Power Systems, vol. 27, no. 2, pp. 951-958, 2011. [DOI:10.1109/TPWRS.2011.2174448]
19. [19] M. S. Pasand and H. Seyedi, "New centralized adaptive under frequency load shedding algorithms," in 2007 Large Engineering Systems Conference on Power Engineering, 2007, pp. 44-48: IEEE. [DOI:10.1109/LESCPE.2007.4437350]
20. [20] V. N. Chuvychin, N. Gurov, S. Venkata, and R. Brown, "An adaptive approach to load shedding and spinning reserve control during underfrequency conditions," IEEE Transactions on Power Systems, vol. 11, no. 4, pp. 1805-1810, 1996. [DOI:10.1109/59.544646]
21. [21] Ashton.P, Taylor.G and et al," Novel application of detrended fluctuation Analysis for state estimation using synchrophasor measurments,", IEEE Transactions on power systems, Vol. 28, No. 2, pp. 1930-1938, 2013. [DOI:10.1109/TPWRS.2013.2248027]

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This Journal is an open access Journal Licensed under the Creative Commons Attribution-NonCommercial 4.0 International License. (CC BY NC 4.0)

© 2025 CC BY-NC 4.0 | Journal of Iranian Association of Electrical and Electronics Engineers

Designed & Developed by : Yektaweb