<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Association of Electrical and Electronics Engineers</title>
<title_fa>نشریه مهندسی برق و الکترونیک ایران</title_fa>
<short_title>Journal of Iranian Association of Electrical and Electronics Engineers</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jiaeee.com</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2676-5810</journal_id_issn>
<journal_id_issn_online>2676-6086</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61882/jiaeee</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1398</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2019</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>16</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارایه یک ساختار کنترلی واحد برای بررسی انطباق مزرعه بادی فراساحلی و متصل به خط انتقال VSC-HVDC بر الزامات شبکه</title_fa>
	<title> Unified Control Structure to Evaluate Grid Code Compatibility of HVDC Interfaced Offshore Wind Power Plant</title>
	<subject_fa>قدرت</subject_fa>
	<subject>Power</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div dir=&quot;ltr&quot;&gt;DOR:&amp;nbsp;98.1000/1735-7152.1398.16.87.0.3.1575.1607&lt;/div&gt;

&lt;div dir=&quot;ltr&quot;&gt;&lt;/div&gt;
&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;انطباق مزرعه بادی فراساحلی متصل به خط انتقال جریان مستقیم بر الزامات شبکه در این مقاله بررسی شده است. کوپلینگ&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;DC&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; در این ساختار منجر به عدم انعکاس اغتشاشات سیستم قدرت در مزرعه بادی فراساحلی می&amp;shy;گردد. در این راستا، سطح ولتاژ لینک &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;DC&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; برای انعکاس وضعیت شبکه ساحلی مدوله شده است. همچنین، اغتشاشات شبکه ساحلی به کمک اندازه&amp;shy;گیری سطح ولتاژ &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;DC&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; و عملکرد مبدل سمت مزرعه بادی در مزرعه بادی فراساحلی منعکس شده است تا از قابلیت پاسخ فرکانسی دینامیکی و فعالیت ضمن خطای توربین&amp;shy;های بادی استفاده گردد. ساختار واحدی کنترلی با تمرکز بر ژنراتور القایی تغذیه دوگانه نیز پیشنهاد شده است که در برگیرنده سه رهیافت مبتنی بر سامانه مخابراتی، مدولاسیون فرکانس و مدولاسیون ولتاژ است و امکان مقایسه این روش&amp;shy;ها را در ساختاری واحد ممکن می&amp;shy;سازد. روشی ترکیبی مدولاسیون ولتاژ و فرکانس نیز پیشنهاد شده است که در آن با تفکیک مناسب مابین دینامیک&amp;shy;های سریع مربوط به خطای اتصال کوتاه شبکه و وقایع فرکانسی آن، به ترتیب از روش مدولاسیون ولتاژ و مدولاسیون فرکانس بهره گرفته شده است. نتایج شبیه&amp;shy;سازی های انجام شده نشان&amp;shy;دهنده توانمندی مشابه هر چهار روش در ارایه پاسخ دینامیکی فرکانسی بوده است. اما با در نظر داشتن فعالیت ضمن خطا، تمامی روش&amp;shy;ها (با فرض تاخیر انتقال داده اندک) به جز روش مدولاسیون فرکانس توانمندی رعایت الزامات ضمن خطای شبکه را داشته&amp;shy;اند. اینطور نتیجه&amp;shy;گیری شده است که مدولاسیون ترکیبی ولتاژ و فرکانس به عنوان برترین رهیافت با تفکیک مناسب مابین دینامیک&amp;shy;های سریع و کند، مزایایی نظیر کمترین سطح افزایش ولتاژ &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;DC&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; ضمن خطا، انحراف از نقطه کار پس از رفع خطا و حفظ ساختار کنترلی متداول را دارد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;</abstract_fa>
	<abstract>Grid code compatibility of HVDC interfaced offshore wind farm is evaluated in this paper. DC coupling causes power system contingencies not to get reflected in the offshore wind farm. In this regard, DC link voltage level is modulated to reflect the status of the onshore power system. Accordingly, onshore power system contingencies are reflected in the offshore wind farm by means of DC link voltage measurement and appropriate exercise of the wind farm HVDC converter. It is to excite dynamic frequency response and Low Voltage Ride Through (LVRT) capabilities of the modern wind turbines. A unified control structure is also proposed for doubly fed induction generator-based offshore wind farms that can model and compare three communication based, frequency modulation based, and voltage modulation based LVRT approaches. Moreover, a hybrid frequency and voltage modulation based approach is proposed in which an appropriate discrimination is embedded between fast transients related to LVRT condition and slow transients related to frequency contingencies. Accordingly, voltage modulation and frequency modulation approaches are utilized under LVRT and frequency events respectively. Simulation results have revealed similar dynamic frequency response capability for all four approaches. Moreover, except frequency modulation approach, remaining approaches have been able to fulfill grid code requirements given agile communication speed. It is concluded that the proposed hybrid frequency and voltage modulation, as the superior approach, has advantages like minimum LVRT DC voltage profile increase and subsequent deviation from theoperating point after the fault and preservation of conventional control structure thanks to appropriate dissociation between slow and fast dynamics. &lt;strong&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;/span&gt;&lt;/strong&gt;</abstract>
	<keyword_fa>الزامات شبکه, خط انتقال VSC-HVDC, روش کاهش توان, ژنراتور القایی تغذیه دوگانه, مزرعه بادی فراساحلی. </keyword_fa>
	<keyword>Doubly fed induction generator, grid codes, offshore wind farm, power reduction method, VSC-HVDC transmission line.</keyword>
	<start_page>87</start_page>
	<end_page>100</end_page>
	<web_url>http://jiaeee.com/browse.php?a_code=A-10-443-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Seyed Saeid</first_name>
	<middle_name></middle_name>
	<last_name> Heidary Yazdi</last_name>
	<suffix></suffix>
	<first_name_fa>سید سعید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حیدری یزدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>saedheidary@aut.ac.ir</email>
	<code>10031947532846004824</code>
	<orcid>10031947532846004824</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Faculty of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- دانشگاه صنعتی امیرکبیر- تهران- ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Jafar </first_name>
	<middle_name></middle_name>
	<last_name>Milimonfared</last_name>
	<suffix></suffix>
	<first_name_fa>جعفر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میلی منفرد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>monfared@aut.ac.ir</email>
	<code>10031947532846004825</code>
	<orcid>10031947532846004825</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical Engineering, Faculty of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- دانشگاه صنعتی امیرکبیر- تهران- ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyed Hamid</first_name>
	<middle_name></middle_name>
	<last_name>Fathi</last_name>
	<suffix></suffix>
	<first_name_fa>سید حمید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فتحی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>fathi@aut.ac.ir</email>
	<code>10031947532846004826</code>
	<orcid>10031947532846004826</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Faculty of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- دانشگاه صنعتی امیرکبیر- تهران- ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
