<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Association of Electrical and Electronics Engineers</title>
<title_fa>نشریه مهندسی برق و الکترونیک ایران</title_fa>
<short_title>Journal of Iranian Association of Electrical and Electronics Engineers</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jiaeee.com</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2676-5810</journal_id_issn>
<journal_id_issn_online>2676-6086</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61882/jiaeee</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1397</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2018</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>15</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>روشی جدید برای تطبیق تصاویر پزشکی هم‌نوع برپایه مدل‌های دگردیس‌پذیر و کاربرد آن برای تصاویر CT قفسه سینه</title_fa>
	<title>A New Method for Medical Image Registration Based on Deformable Models: Application for Thorax CT Images</title>
	<subject_fa>مخابرات</subject_fa>
	<subject>Communication</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;در تصاویر &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;strong&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;CT&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt; چهاربعدی، ثبت تغییر شکل قفسه سینه در اثر حرکات بافت و تنفس امکان&#8204;پذیر می&#8204;باشد. لذا، برای ارزیابی تغییرات شکل قفسه سینه لازم است تا تصاویر ثبت شده در زمان&#8204;های مختلف با یکدیگر تطبیق داده شوند. در این مقاله یک الگوریتم جدید برپایه مدل&#8204;های دگردیس&#8204;پذیر برای تطبیق غیرسخت تصاویر پزشکی ارائه شده است. تابعی انرژی روش پیشنهادی از دو جمله انرژی&#8204;های داخلی و خارجی تشکیل شده که از کمینه&#8204;سازی آنها میدان برداری بهینه (برای توصیف جابجایی پیکسل&#8204;ها) بدست خواهد آمد. انرژی خارجی بر پایه معیار پرکاربرد کمترین مربعات خطا (با در نظر گرفتن ضریب مقیاس روشنایی) توسعه داده شده است. از آنجا که انتظار می&#8204;رود الگوریتم تطبیق بتواند تبدیل&#8204;های انتقال، تغییر مقیاس و دوران محلی را پیاده&#8204;سازی نماید، برای انرژی خارجی (منظم کننده) معیار کمینه&#8204;سازی اندازه مشتق دوم میدان جابجایی پیشنهاد گردیده است. برای ارزیابی الگوریتم پیشنهادی از تصاویر &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;strong&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;CT&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt; سه&#8204;بعدی (موجود در پایگاه داده &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:times-roman,serif;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;http://www.dir-lab.com&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;) در دو وضعیت بیشترین دم و بیشترین بازدم استفاده شده است. در تصاویر مورد استفاده مختصات تعدادی از نقاط متناظر در دو تصویر مشخص بوده و می&#8204;توان دقت تطبیق را از لحاظ مکانی مورد بررسی قرار داد. برای ارزیابی روش پیشنهادی از یک پایگاه داده شامل تصاویر &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;strong&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;CT&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt; چهاربعدی 5 فرد سالم استفاده شده است. نتایج تجربی نشان داد که میانگین خطای روش پیشنهادی در مقایسه با 11 روش رقیب، حداقل 8% بهبود داشته است.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;</abstract_fa>
	<abstract>In 4D CT images of the thorax, deformation is caused by both the tissue movement and breathing. Tissue movement can be estimated at various time intervals by image registrstion. In this paper, a new deformable model is proposedfor non-regid medical image resgistration. The energy funational of the suggested algorithm consists of two internal (regulator) and external terms. By minimization of the energy functional, the optimal vector field which indicates the translation vectors of image pixels is obtained. The external energy is developed based on the well-known least-square-errors cost function (with the scaling coefficient of gray-levels). However, for local implementation of the translation, scaling, and rotation, we proposed minimization of the amplitude of the second-derivative of the vector filed as the internal energy term. For solution quality assessment, a number of 3D thorax CT images (available at the database http://www.dir-lab.com) at the end-inhale and end-exhale phases were used. In all benchmark images, the precise positions of a number of anatomical index points had been indicated by an expert. The performance of the proposed method can be evaluated by computing the distance between the corresponding index points in two images after registration. Experimantal results demonstrated that the average registration error of the proposed algorithm was at least 8% better than those of 11 counterpart algorithms.</abstract>
	<keyword_fa>تطبیق تصاویر, مدل‌های دگردیس‌پذیر, تصاویر CT چهار بعدی</keyword_fa>
	<keyword>Non-rigid image registration, Deformable models, 4D CT images.</keyword>
	<start_page>69</start_page>
	<end_page>80</end_page>
	<web_url>http://jiaeee.com/browse.php?a_code=A-10-451-6&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>vahid</first_name>
	<middle_name></middle_name>
	<last_name>Sarani Rad</last_name>
	<suffix></suffix>
	<first_name_fa>وحید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سارانی راد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>va_sa884@um.ac.ir</email>
	<code>10031947532846002887</code>
	<orcid>10031947532846002887</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical Engineering, Ferdowsi University, Mashhad, Iran.</affiliation>
	<affiliation_fa>گروه مهندسی برق، دانشگاه فردوسی مشهد</affiliation_fa>
	 </author>


	<author>
	<first_name>shiva</first_name>
	<middle_name></middle_name>
	<last_name>sanati</last_name>
	<suffix></suffix>
	<first_name_fa>شیوا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صنعتی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>shiva.sanati@stu.um.ac.ir</email>
	<code>10031947532846002888</code>
	<orcid>10031947532846002888</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Computer Engineering, Ferdowsi University, Mashhad, Iran.</affiliation>
	<affiliation_fa>گروه مهندسی کامپیوتر، دانشگاه فردوسی مشهد</affiliation_fa>
	 </author>


	<author>
	<first_name>zahra</first_name>
	<middle_name></middle_name>
	<last_name>Sheikholeslami</last_name>
	<suffix></suffix>
	<first_name_fa>زهرا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شیخ الاسلامی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>z.sheikholeslami@mail.um.ac.ir</email>
	<code>10031947532846002889</code>
	<orcid>10031947532846002889</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Computer Engineering, Ferdowsi University, Mashhad, Iran.</affiliation>
	<affiliation_fa>گروه مهندسی کامپیوتر، دانشگاه فردوسی مشهد</affiliation_fa>
	 </author>


	<author>
	<first_name>mahdi</first_name>
	<middle_name></middle_name>
	<last_name>Saadatmand Tarzjan</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سعادتمند طرزجان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>saadatmand@um.ac.ir</email>
	<code>10031947532846002890</code>
	<orcid>10031947532846002890</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant professor, Department of Electrical Engineering, Ferdowsi University, Mashhad, Iran.</affiliation>
	<affiliation_fa>آزمایشگاه تصویربرداری پزشکی، گروه مهندسی برق، دانشگاه فردوسی مشهد</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
