<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Association of Electrical and Electronics Engineers</title>
<title_fa>نشریه مهندسی برق و الکترونیک ایران</title_fa>
<short_title>Journal of Iranian Association of Electrical and Electronics Engineers</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jiaeee.com</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2676-5810</journal_id_issn>
<journal_id_issn_online>2676-6086</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61882/jiaeee</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1400</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2021</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<volume>18</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>کلیدزنی سنکرون در خط انتقال جبران سازی نشده با در نظر گرفتن اثر ولتاژ کوپلینگ بین فازها</title_fa>
	<title>Synchronous Switching of Uncompensated Transmission Line, by Considering the Effect of Coupling Voltage between the Phases</title>
	<subject_fa>قدرت</subject_fa>
	<subject>Power</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;strong&gt;کلید زنی سنکرون باعث کاهش حالت&amp;shy;های گذرای ایجاد شده ناشی از کلید زنی در خط انتقال می&amp;shy;شود. الگوریتم ارائه شده در این مقاله در لحظه&amp;shy; ارسال فرمان وصل کلید توسط اپراتور، با در نظر گرفتن ولتاژ کوپلینگ بین فازها، نحوه بسته شدن سنکرون هر سه فاز کلید خط انتقال جبران سازی نشده را در وضعیتی که انتهای خط باز باشد، کنترل می&amp;shy;کند. الگوریتم مذکور با بدست آوردن مقادیر تاخیر در ارسال فرمان به هر فاز کلید بر مبنای روابط ریاضی، به ازای انواع مختلف پیکر بندی خط انتقال (ترانسپوزه بودن یا نبودن، متعادل بودن یا نبودن) و مقادیر مختلف طول خط و زمان&amp;shy;های عملکرد مکانیکی برای هر فاز کلید، بستن سنکرون هر سه فاز را کنترل می&amp;shy;کند. نتایج بدست آمده حاکی از آن است که با اعمال این الگوریتم در حوزه عملکرد مذکور، با توجه به زمان نمونه برداری، هر فاز کلید با خطای حداکثر سه نمونه (معادل اختلاف 3/0 میلی ثانیه از زمان بهینه بستن کلید) در وضعیت صفر ولتاژ بسته می&amp;shy;شود.&lt;/strong&gt;&lt;br&gt;
&amp;nbsp;</abstract_fa>
	<abstract>The synchronous switching reduces the transients caused by switching of the transmission line. By considering the coupling voltages between phases, the proposed algorithm controls the synchronous closing of all three phases of an uncompensated transmission, whenever the other end of the line is open. The algorithm by calculating the delay times for sending commands to each phase of CB, based on mathematical relations, controls the switching of the three phases of CB. It can be applied for different types of configuration of the transmission line (whether they are transposed or not, and balanced or not), various line lengths, the mechanical operation time for each phase of CB, and independent of the opening time of each phase. The results show that by applying this algorithm each phase of CB is closed in the zero-voltage state with a maximum error of three samples.&lt;br&gt;
&amp;nbsp;</abstract>
	<keyword_fa>کلید زنی سنکرون, ولتاژ کوپلینگ, خط انتقال</keyword_fa>
	<keyword>Synchronous Switching, Coupling voltage, Transmission Line.</keyword>
	<start_page>83</start_page>
	<end_page>92</end_page>
	<web_url>http://jiaeee.com/browse.php?a_code=A-10-209-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>S. Mohammad</first_name>
	<middle_name></middle_name>
	<last_name>Shahrtash</last_name>
	<suffix></suffix>
	<first_name_fa>سید محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شهرتاش</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>shahrtash@iust.ac.ir</email>
	<code>10031947532846008749</code>
	<orcid>10031947532846008749</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Center of Excellence for Power System Automation and Operation, Iran University of Science &amp; Technology</affiliation>
	<affiliation_fa>قطب علمی اتوماسیون و بهره برداری سامانه قدرت - دانشگاه علم و صنعت ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Karimonnafs</first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>علیرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کریم النفس</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>alireza.kk.1371@gmail.com</email>
	<code>10031947532846008750</code>
	<orcid>10031947532846008750</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Center of Excellence for Power System Automation and Operation, Iran University of Science &amp; Technology</affiliation>
	<affiliation_fa>قطب علمی اتوماسیون و بهره برداری سامانه قدرت - دانشگاه علم و صنعت ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
