<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Association of Electrical and Electronics Engineers</title>
<title_fa>نشریه مهندسی برق و الکترونیک ایران</title_fa>
<short_title>Journal of Iranian Association of Electrical and Electronics Engineers</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jiaeee.com</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2676-5810</journal_id_issn>
<journal_id_issn_online>2676-6086</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61882/jiaeee</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>14</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مکان یابی خطا در شبکه توزیع با حضور منابع تولید پراکنده به روش امپدانسی با استفاده از مدل خط متوسط</title_fa>
	<title>Fault Location in Power Distribution Network with Presence of Distributed Generation Resources Using Impedance Based Method and Applying π Line Model</title>
	<subject_fa>قدرت</subject_fa>
	<subject>Power</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;اتصال منابع تولید پراکنده به شبکه&amp;shy;های توزیع علی رغم مزایایی که برای شبکه دارد باعث غربالی شدن فیدر توزیع از حالت شعاعی می&amp;shy;شود. لذا شیوه های مرسوم حفاظت در این شبکه کارآمد نبوده و یافتن محل خطا باوجود آنها می&amp;shy;تواند بسیار مشکل باشد. مکان&amp;shy;یابی خطای امپدانسی با حضور منابع تولید پراکنده از منظر تأمین پایداری و ایمنی سیستم از اهمیت بالایی برخوردار است. در این مقاله یک روش امپدانسی برای فاصله یابی خطا در شبکه توزیع با حضور منابع تولید پراکنده فتوولتاییک ارایه شده است. در این روش جریان و ولتاژ در ابتدای فیدر و محل منابع تولید پراکنده اندازه گیری شده و با استفاده از مدل &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;&amp;pi;&lt;/span&gt;&lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt; خط، مکان خطا محاسبه می&amp;shy;گردد. برای این منظور یک شبکه 11 باسه واقعی در نرم افزار &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-weight:normal;&quot;&gt;&lt;span style=&quot;font-size:9.0pt;&quot;&gt;MATLAB&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt; شبیه سازی شده است و حساسیت روش پیشنهادی در برابر انواع خطاها، مقاومت&amp;shy;های مختلف و زاویه&amp;shy;های شروع خطای مختلف و توان&amp;shy;های مختلف مورد بررسی قرار گرفته است&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-family:b nazanin;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;و نتایج حاصله نشان از دقت بالای الگوریتم است&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-weight:normal;&quot;&gt;&lt;span style=&quot;font-size:10.0pt;&quot;&gt;.&lt;/span&gt;&lt;/span&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;In this paper, an improved impedance based method has been proposed for fault location in power distribution network with presence of photovoltaic distributed generation resources. Within this method, current and voltage are measured at the beginning of feeder and at the location of distributed generation resources. The &lt;strong&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;pi;&lt;/span&gt;&lt;/strong&gt; line model is used for improving the accuracy of the suggested method. To evaluate the accuracy of the proposed method, the modified 11 node test Feeder is simulated in the Matlab software and sensitivity of the suggested method was investigated against the different fault distances fault types, fault resistances and fault inception angles. The results indicate the high accuracy of the algorithm.&lt;/div&gt;
</abstract>
	<keyword_fa>شبکه توزیع؛ مکان یابی خطا؛ مدل خط متوسط؛ منابع تولید پراکنده؛ فتوولتاییک</keyword_fa>
	<keyword>distribution network, fault location, π line model, distributed generation resources, photovoltaic</keyword>
	<start_page>79</start_page>
	<end_page>90</end_page>
	<web_url>http://jiaeee.com/browse.php?a_code=A-10-1-241&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>R.</first_name>
	<middle_name></middle_name>
	<last_name>Dashti</last_name>
	<suffix></suffix>
	<first_name_fa>رحمن </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دشتی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846001815</code>
	<orcid>10031947532846001815</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه مهندسی برق، دانشکده مهندسی دانشگاه خلیج فارس- بوشهر 7516913817- ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Ghasemi</last_name>
	<suffix></suffix>
	<first_name_fa>محسن </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قاسمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846001816</code>
	<orcid>10031947532846001816</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانش‌آموخته کارشناسی ارشد- گروه مهندسی برق، دانشکده تحصیلات تکمیلی آزاد اسلامی واحد بوشهر - بوشهر- ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
