<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Association of Electrical and Electronics Engineers</title>
<title_fa>نشریه مهندسی برق و الکترونیک ایران</title_fa>
<short_title>Journal of Iranian Association of Electrical and Electronics Engineers</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jiaeee.com</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2676-5810</journal_id_issn>
<journal_id_issn_online>2676-6086</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61882/jiaeee</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1387</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2008</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>5</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>فاصله یابی خطا در خطوط انتقال نیرو با سه پایانه در حوزه زمان با استفاده از  اندازه گیریهای همزمان و مدل گسترده خط انتقال</title_fa>
	<title>Fault Location in Three Terminal Transmission Lines: Time Domain Distributed Line Model and Synchronous Measurements</title>
	<subject_fa>قدرت</subject_fa>
	<subject>Power</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;روشهای فاصله&amp;shy;یابی خطا با استفاده از ولتاژها و جریانهای یک طرف خط انتقال برای سیستمهای با سه پایانه و بیشتر کاربردی ندارند. تاکنون روشهای &lt;/strong&gt;&lt;strong&gt;مختلفی &lt;/strong&gt;&lt;strong&gt;جهت حل&lt;/strong&gt;&lt;strong&gt; مسئله&lt;/strong&gt;&lt;strong&gt; فاصله&amp;shy;یابی خطا در خطوط با چند پایانه ارائه شده که عمدتاً از مدل های فشرده و یا مدل گسترده حوزه فرکانس خط انتقال استفاده شده است. &lt;/strong&gt;&lt;strong&gt;برای حل مسئله فاصله یابی خطا در این خطوط قبل از تعیین فاصله تا محل خطا بایستی روشی جهت تعیین بخش خطا دار ارائه گردد. &lt;/strong&gt;&lt;strong&gt;در&lt;/strong&gt; &lt;strong&gt;این مقاله روشی برای&lt;/strong&gt;&lt;strong&gt; تعیین بخش &lt;/strong&gt;&lt;strong&gt;خطا&lt;/strong&gt;&lt;strong&gt;دار خط انتقال و همچنین الگوریتمی برای&lt;/strong&gt;&lt;strong&gt; فاصله یابی&lt;/strong&gt;&lt;strong&gt; محل خطا&lt;/strong&gt;&lt;strong&gt; با استفاده از مدل گسترده&lt;/strong&gt;&lt;strong&gt; خط انتقال در&lt;/strong&gt;&lt;strong&gt; حوزه زمان&lt;/strong&gt;&lt;strong&gt; ارائه شده است که در آن&lt;/strong&gt;&lt;strong&gt; پنجره اطلاعاتی&lt;/strong&gt;&lt;strong&gt; مورد نیاز برای اجرای الگوریتم، پنجره ای کوتاهتر از &lt;/strong&gt;&lt;strong&gt;نیم سیکل&lt;/strong&gt;&lt;strong&gt; می&amp;shy;باشد. در این روش اطلاعات هر سه پایانه برای اجرای الگوریتم مورد نیاز است. روش پیشنهادی به مقاومت و نوع خطا وابسته نبوده و زاویه شروع خطا، جریان بار و امپدانس منابع تاثیری بر روی دقت آن ندارند. همچنین نیازی به فیلتر کردن مولفه &lt;/strong&gt;&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;DC&lt;/span&gt;&lt;/strong&gt;&lt;strong&gt; میراشونده و مولفه&amp;shy;های فرکانس بالای موجود در شکل موجهای ولتاژ و جریان وجود ندارد. &lt;/strong&gt;&lt;strong&gt;شبیه سازی&lt;/strong&gt;&lt;strong&gt; یک سیستم قدرت نمونه &lt;/strong&gt;&lt;strong&gt;توسط نرم&amp;shy;افزار &lt;/strong&gt;&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;EMTP/ATP&lt;/span&gt;&lt;/strong&gt;&lt;strong&gt; در شرایط عملکردی متفاوت&lt;/strong&gt; &lt;strong&gt;و استفاده از داده&amp;shy;های حاصل در محیط نرم&amp;shy;افزار&amp;nbsp; &lt;/strong&gt;&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;MATLAB&lt;/span&gt;&lt;/strong&gt;&lt;strong&gt;&amp;nbsp; برای اجرای الگوریتم صحت و دقت این روش را تایید&lt;/strong&gt;&lt;strong&gt; می&amp;shy;کند.&lt;/strong&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;Conventional fault location methods using voltages and currents of one terminal are not applicable to multiterminal transmission lines. So far some techniques have been presented to solve fault location problem for multi-terminal transmission lines. In these methods, lumped or distributed frequency domain models of transmission lines have been used. In multi terminal lines, faulty section should be detected before fault location estimation. In this paper, a method based on time domain model of transmission line is presented to identify the faulty section and to determine the location of faults for three-terminal transmission lines. In the suggested method, samples of voltages and currents at all three terminals are used for calculating the location of the fault. The proposed algorithm is independent of fault resistance, insensitive to load current and fault inception angle. Furthermore, in the method neither any knowledge about source impedance nor the fault type classification is required. Filtering of dc and high frequency components of voltages and currents signals are not necessary. The simulation results, using EMTP/ATP and MATLAB software, confirm the accuracy and precision of the proposed method.&lt;/p&gt;
</abstract>
	<keyword_fa>خطوط انتقال سه پایانه, حفاظت خطوط انتقال,  فاصله یابی خطا, تعیین قسمت خطادار, مدل گسترده خط انتقال در حوزه زمان.</keyword_fa>
	<keyword>Three-terminal transmission line, transmission line protection, Fault location, Fault section detection, Distributed time domain line model.</keyword>
	<start_page>59</start_page>
	<end_page>67</end_page>
	<web_url>http://jiaeee.com/browse.php?a_code=A-10-1-186&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>E.</first_name>
	<middle_name></middle_name>
	<last_name>Kamyab</last_name>
	<suffix></suffix>
	<first_name_fa>عباداله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa> کامیاب </last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600667</code>
	<orcid>1003194753284600667</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M. </first_name>
	<middle_name></middle_name>
	<last_name>Javidi</last_name>
	<suffix></suffix>
	<first_name_fa>محمد حسین </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جاویدی </last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600668</code>
	<orcid>1003194753284600668</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>J.</first_name>
	<middle_name></middle_name>
	<last_name>Sadeh</last_name>
	<suffix></suffix>
	<first_name_fa>جواد </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ساده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600669</code>
	<orcid>1003194753284600669</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
