<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Association of Electrical and Electronics Engineers</title>
<title_fa>نشریه مهندسی برق و الکترونیک ایران</title_fa>
<short_title>Journal of Iranian Association of Electrical and Electronics Engineers</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jiaeee.com</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2676-5810</journal_id_issn>
<journal_id_issn_online>2676-6086</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61882/jiaeee</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1403</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2024</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<volume>21</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>فرمولاسیون جریان‌های لحظه‌ای شاخه خطا در خطوط انتقال دو‌مداره نامتقارن طی خطاهای Cross-Country با درنظر‌گرفتن موقعیت مکانی خطاهای تکفاز</title_fa>
	<title>Formulation of Fault-Branch Currents During Cross-Country Faults on Asymmetrical Double-Circuit Transmission Lines Considering Status of Line-Ground Faults’ locations</title>
	<subject_fa>قدرت</subject_fa>
	<subject>Power</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot; style=&quot;font-size:11.0pt&quot;&gt;خطاهای &lt;/span&gt;Cross-Country&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot; style=&quot;font-size:11.0pt&quot;&gt; خطاهای نامتعارف در خطوط انتقال دو&amp;shy;&amp;shy;&amp;shy;&amp;shy;&amp;shy;&amp;shy;مداره بوده که مشتمل بر دو خطای تکفاز به زمین در دو فاز از شش فاز این خطوط و در دو موقعیت مکانی متفاوت می&amp;shy;باشند. در مورد این خطاها، داشتن روابط تحلیلی توصیف&amp;shy;کننده جریان&amp;shy;های شاخه خطا (جریان&amp;shy;های لحظه&amp;shy;ای جاری شده از فازها به شاخه خطا)، مبنا و ابزاری کارا برای پرداختن به موضوعات تحقیقاتی با اهمیتی همچون تحلیل خطا، حفاظت و رله گذاری، جایابی و دسنه بندی خطا بوده که در تحقیقات پیشین بدان پرداخته نشده است. در این مقاله، با تحلیل مدل حوزه زمانی خطوط دو&amp;shy;مداره نامتقارن، فرمولاسیون جریان&amp;shy;های لحظه&amp;shy;ای شاخه خطا طی خطاهای &lt;/span&gt;Cross-Country&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot; style=&quot;font-size:11.0pt&quot;&gt; با درنظر گرفتن موقعیت خطاهای تکفاز مشتمل ارائه می&amp;shy;گردد. در نتیجه این فرمولاسیون، روابط صریح حاکم بر جریان&amp;shy;های لحظه&amp;shy;ای برحسب جریان&amp;shy;های سه فاز یک انتهای خط و فواصل خطا از همان انتها استخراج می&amp;shy;شود. این روابط، پرداختن به موضوعات تحقیقاتی فوق الذکر که در حوزه زمان توسعه داده می&amp;shy;شود را تسهیل کرده و دارای کاربرد عملی می&amp;shy;باشد. روابط بدست آمده از طریق شبیه سازی نرم افزاری در &lt;/span&gt;PSCAD/EMTDC&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot; style=&quot;font-size:11.0pt&quot;&gt; با استفاده از مدل معتبر خط دو&amp;shy;مداره ارزیابی شده و اعتبار آن مورد تایید قرار می&amp;shy;گیرد.&lt;/span&gt;&lt;br&gt;
&amp;nbsp;</abstract_fa>
	<abstract>Cross-Country faults are atypical faults occurring on double-circuit transmission lines, which include two line-ground faults on two out of six phases of the line at different locations. As for these types of faults, having access to analytic equations characterizing the fault-branch currents is regarded as a functional tool for dealing with critical issues such as fault analysis, protection/relaying, and fault location/classification. This matter has not been dealt with in the previous research in the literature yet. From analyzing the circuit model of asymmetrical double-circuit lines on a time domain basis, this paper develops a formulation of the instantaneous fault-branch currents during CCFs, considering status of L-G faults&amp;rsquo; locations. As a result, clear-cut formulas governing the instantaneous currents flowing from the faulty phases into the fault branches during CCFs are obtained. They are acquired regarding the line one-end circuits&amp;rsquo; phase currents and the fault locations measured from the same end. The proposed formulas would facilitate dealing with applications mentioned above, particularly those developed in time domain. The formulas are validated via the simulation studies in PSCAD/EMTDC with an accurate time-domain model of the asymmetrical lines.&lt;br&gt;
&amp;nbsp;</abstract>
	<keyword_fa>خطاهای Cross-Country, جریان‌های لحظه‌ای شاخه خطا, خطوط انتقال دو‌مداره نامتقارن, موقعیت مکانی خطاهای تکفاز</keyword_fa>
	<keyword>Cross-Country faults, Fault-branch currents, Asymmetrical double-circuit transmission lines, Statues of L-G faults’ locations.</keyword>
	<start_page>147</start_page>
	<end_page>154</end_page>
	<web_url>http://jiaeee.com/browse.php?a_code=A-10-1140-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Hamed</first_name>
	<middle_name></middle_name>
	<last_name>Abdollahzadeh</last_name>
	<suffix></suffix>
	<first_name_fa>حامد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عبداله زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>H.abdollahzadeh@gmail.com</email>
	<code>100319475328460011746</code>
	<orcid>100319475328460011746</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical Engineering, East-Tehran Branch, Islamic Azad University</affiliation>
	<affiliation_fa>گروه مهندسی برق، واحد تهران شرق، دانشگاه آزاد اسلامی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hamid Reza</first_name>
	<middle_name></middle_name>
	<last_name>Matinafshar</last_name>
	<suffix></suffix>
	<first_name_fa>حمید رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>متین افشار</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>H.R.Matinafshar@gmail.com</email>
	<code>100319475328460011747</code>
	<orcid>100319475328460011747</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, East-Tehran Branch, Islamic Azad University</affiliation>
	<affiliation_fa>گروه مهندسی برق، واحد تهران شرق، دانشگاه آزاد اسلامی، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
