<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Association of Electrical and Electronics Engineers</title>
<title_fa>نشریه مهندسی برق و الکترونیک ایران</title_fa>
<short_title>Journal of Iranian Association of Electrical and Electronics Engineers</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jiaeee.com</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2676-5810</journal_id_issn>
<journal_id_issn_online>2676-6086</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61882/jiaeee</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1403</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2024</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>21</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>وصل مجدد خودکار تک‌فاز تطبیقی بسیار سریع در خطوط انتقال فشارقوی</title_fa>
	<title>Ultra-Fast Adaptive Single-Pole Auto-Reclosing in High-Voltage Transmission Lines</title>
	<subject_fa>قدرت</subject_fa>
	<subject>Power</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;با توجه به اهمیت بسیار بالای خطوط انتقال فشارقوی در سیستم&#8204;های قدرت و اینکه اکثر خطاهای رخ داده در این خطوط تک&#8204;فاز به زمین و از نوع گذرا هستند، سرعت عملکرد رله بازبست اتوماتیک تک&#8204;فاز به زمین نقش بسیار مهمی در پایداری سیستم قدرت خواهد داشت. از این رو در این مقاله یک الگوریتم حفاظتی بسیار سریع مبتنی بر &lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;CUSUM&lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt; جهت بهبود عملکرد رله وصل مجدد تک&#8204;فاز پیشنهاد گردیده است. طرح پیشنهادی بدین صورت عمل می&#8204;کند که از ولتاژ ترمینال یک طرف خط انتقال فشارقوی نمونه&#8204;برداری می&#8204;کند. سپس با اعمال &lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;CUSUM&lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt; بر روی ولتاژ نمونه&#8204;برداری شده و اعمال تنظیمات مربوطه، لحظه وصل مجدد فاز معیوب تعیین می&#8204;گردد. نتایج شبیه&#8204;سازی&#8204;های گسترده در محیط نرم&#8204;افزاری &lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;EMTP-RV&lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt; بر روی یک سیستم قدرت نمونه &lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;kV&lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt; 400 نشان میدهد که طرح حفاظتی پیشنهادی در شناسایی لحظه بازبست موفقیت&#8204;آمیز بسیار دقیق عمل کرده است. سرعت بسیار بالای روش پیشنهادی، عدم نویزپذیری و پیچیدگی محاسباتی بسیار پایین روش، استفاده از آن را برای کاربردهای صنعتی فراهم می&#8204;کند.&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;</abstract_fa>
	<abstract>&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;High-voltage transmission lines (HVTLs) are one of the important parts of power systems exposed to different types of fault. As most of the faults that occur in HVTLs are single line to ground (SLG) and transient type, the operating speed of the single-pole auto-reclosing (SPAR) will play an important role in the stability of power systems. In this paper, an ultra-fast protection strategy is proposed based on the cumulative sum (CUSUM) algorithm to improve the performance of the SPAR. In the proposed protection scheme, first, the terminal voltage of one side of the HVTL is sampled. Then by employing the CUSUM algorithm for the sampled voltage and applying the corresponding settings, the reclosing moment of the faulty phase is determined. The results of extensive simulations in the EMTP-RV software environment on a 400 kV test power system show that the proposed protection scheme has been very accurate in identifying the moment of successful reclosing. The ultra-fast performance and low computational complexity of the proposed method along with its robustness to noise make it useful for practical applications.&lt;b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;font-family:&quot;B Nazanin&quot;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;</abstract>
	<keyword_fa>خطوط انتقال فشارقوی, خطای گذرا و دائم, بازبست اتوماتیک تک‌فاز تطبیقی و CUSUM.</keyword_fa>
	<keyword>Transient and Permanent Faults, High Voltage Transmission Line, Single-Pole Auto-Reclosing and CUSUM.</keyword>
	<start_page>157</start_page>
	<end_page>166</end_page>
	<web_url>http://jiaeee.com/browse.php?a_code=A-10-2395-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mojtaba</first_name>
	<middle_name></middle_name>
	<last_name>Aliyari</last_name>
	<suffix></suffix>
	<first_name_fa>مجتبی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علی یاری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Mojtaba.aliyari@iaukhsh.ac.ir</email>
	<code>100319475328460013068</code>
	<orcid>100319475328460013068</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Khomeinishahr branch, Islamic Azad University</affiliation>
	<affiliation_fa>گروه برق- واحد خمینی شهر- دانشگاه آزاد اسلامی- خمینی شهر</affiliation_fa>
	 </author>


	<author>
	<first_name>mohsen</first_name>
	<middle_name></middle_name>
	<last_name>jannati</last_name>
	<suffix></suffix>
	<first_name_fa>محسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جنتی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m.jannati@shr.ui.ac.ir</email>
	<code>100319475328460013069</code>
	<orcid>100319475328460013069</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical Engineering, Shahreza Campus, University of Isfahan</affiliation>
	<affiliation_fa>گروه مهندسی برق- مرکز آموزش عالی شهرضا، دانشگاه اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name>Milad</first_name>
	<middle_name></middle_name>
	<last_name>Dolatshahi</last_name>
	<suffix></suffix>
	<first_name_fa>میلاد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دولتشاهی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>dolatshahi@iaukhsh.ac.ir</email>
	<code>100319475328460013070</code>
	<orcid>100319475328460013070</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Khomeinishahr branch, Islamic Azad University</affiliation>
	<affiliation_fa>گروه برق- واحد خمینی شهر- دانشگاه آزاد اسلامی- خمینی شهر</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Mahdi</first_name>
	<middle_name></middle_name>
	<last_name>Rezaei</last_name>
	<suffix></suffix>
	<first_name_fa>محمدمهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رضایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mm.rezaei@iaukhsh.ac.ir</email>
	<code>100319475328460013071</code>
	<orcid>100319475328460013071</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Khomeinishahr branch, Islamic Azad University</affiliation>
	<affiliation_fa>گروه برق- واحد خمینی شهر- دانشگاه آزاد اسلامی- خمینی شهر</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
