<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Association of Electrical and Electronics Engineers</title>
<title_fa>نشریه مهندسی برق و الکترونیک ایران</title_fa>
<short_title>Journal of Iranian Association of Electrical and Electronics Engineers</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jiaeee.com</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2676-5810</journal_id_issn>
<journal_id_issn_online>2676-6086</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61882/jiaeee</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>20</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>در مدارقرارگیری نیروگاه ها با درنظرگیری اشکال عملکردی ذخیره-سازهای ترکیبی در تامین پایداری فرکانسی</title_fa>
	<title>Unit Commitment Considering the malfunctioned Operation of Hybrid Energy Storage Systems in Frequency Stability Support</title>
	<subject_fa>قدرت</subject_fa>
	<subject>Power</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;در مدار قرارگیری نیروگاه مقید به امنیت، به&#8204;عنوان یک روش پیشگیرانه تأمین پاسخ فرکانسی شبکه می&amp;shy;تواند منجر به نفوذ بیشتر منابع تجدیدپذیر انرژی با حفظ پارامترهای پاسخ فرکانسی در محدوده مجاز شود و نیاز به اقدامات اصلاح&amp;shy;کننده از قبیل بارزدایی زیر فرکانسی یا خاموشی سراسری را کاهش دهد. تاکنون دیدگاه بهره&amp;shy;برداری از اینرسی مجازی واحدهای ذخیره&amp;shy;ساز دارای اینورتر متصل به شبکه، به&#8204;صورت بدبینانه (عدم تأمین اینرسی مجازی) و خوش&#8204;بینانه (تأمین بی&amp;shy;نقص پاسخ فرکانسی) بوده است. اما در نگاه واقع&#8204;بینانه ممکن است سیستم تأمین پاسخ فرکانسی با اختلالی مواجه شود و عملکرد نادرستی از خود نشان دهد که در این مقاله به مدل&amp;shy;سازی و تحلیل ابعاد فنی و اقتصادی آن پرداخته شده است. عدم تشخیص صحیح سنسورها، عملکرد نادرست سیستم کنترل، عدم تزریق صحیح توان ذخیره&amp;shy;ساز، خرابی اینورتر، تنظیم نادرست پارامترها و ... همگی از عوامل منجر به نقص عملکرد سیستم ذخیره&#8204;ساز هستند، اما در این مقاله به&#8204;منظور حفظ جامعیت مدل، از پرداختن به علت عملکرد نامناسب سیستم ذخیره&#8204;ساز اجتناب شده و صرفاً به درنظرگرفتن اثر آن یعنی امکان عدم مشارکت صحیح سیستم&amp;shy; ذخیره&amp;shy;ساز اکتفا شده&amp;shy;است. در این مدل جهت درنظرگرفتن پایداری فرکانسی سیستم، محدودیت&#8204;های نقطه قعر و نرخ تغییرات اولیه فرکانس به&#8204;صورت قیود خطی به مسئله برنامه&#8204;ریزی مقاوم خطی عدد صحیح، افزوده شده و جهت حل آن از ادغام حلگرهای &lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;MOSEK&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt; و &lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;YALMIP&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt; استفاده شده است. نتایج حاصل از پیاده&#8204;سازی این مدل در شبکه &lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;IEEE-RTS96&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt; نشان از تخطی قیود فرکانسی در صورت چشم&amp;shy;پوشی از اختلال سیستم&amp;shy;های ذخیره&amp;shy;ساز دارد که با صرف هزینه بیشتر بر واحدهای پاسخ سریع، آنلاین نگه&#8204;داشتن واحدهای بیشتر و رعایت ظرفیت آزاد نیروگاهی می&amp;shy;توان از وقوع آن جلوگیری کرد.&lt;/span&gt;&lt;/span&gt;</abstract_fa>
	<abstract>&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;Using security-constrained unit commitment as a preventative method of supplying power system frequency response can increase the penetration of renewable energy sources while maintaining frequency response parameters within their allowable range. Moreover, it can reduce the need for corrective actions such as under-frequency load shedding and can prevent power blackouts. So far, there have been two views about the virtual inertia of grid-connected energy storage units, pessimistic (lack of virtual inertia) and optimistic (failure-free frequency response). However, in reality, the frequency response supply system may experience malfunction and incorrect operation, which is modeled and analyzed in this paper from a techno-economic standpoint. False sensor detection, control system malfunction, wrong power injection of energy storage, inverter failure, improper parameter setting, etc., can all be considered disruptive factors. However, in order to have a more general model, the article avoids dealing with the reason behind the poor performance of the storage system and focuses only on its effects, i.e., the possibility of the storage system not participating correctly. The proposed model takes into account the system&amp;#39;s frequency stability by linearly integrating the nadir frequency and the rate of change of frequency limits to the robust mixed-integer linear programming model with YALMIP and MOSEK solvers. The results of implementing this model in the IEEE-RTS96 network show that neglecting energy storage system malfunctions can lead to violations of frequency constraints that must be compensated by increasing costs and keeping more online units with more free headroom.&lt;b&gt;&lt;span dir=&quot;RTL&quot; style=&quot;font-family:&quot;B Nazanin&quot;&quot; lang=&quot;FA&quot;&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;</abstract>
	<keyword_fa>در مدار قرارگیری نیروگاه, پایداری فرکانسی, ذخیره سازهای ترکیبی, منابع انرژی تجدیدپذیر</keyword_fa>
	<keyword>Unit Commitment, Frequency Stability, Hybrid Energy Storage Systems, Renewable Energy Resources</keyword>
	<start_page>147</start_page>
	<end_page>162</end_page>
	<web_url>http://jiaeee.com/browse.php?a_code=A-10-2612-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Houshang</first_name>
	<middle_name></middle_name>
	<last_name>Abiari</last_name>
	<suffix></suffix>
	<first_name_fa>هوشنگ</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آبیاری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>h_abyari@iauyazd.ac.ir</email>
	<code>100319475328460011460</code>
	<orcid>100319475328460011460</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Yazd Branch, Islamic Azad University</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- واحد یزد- دانشگاه آزاد اسلامی</affiliation_fa>
	 </author>


	<author>
	<first_name>Tahere</first_name>
	<middle_name></middle_name>
	<last_name>Daemi</last_name>
	<suffix></suffix>
	<first_name_fa>طاهره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دائمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>t.daemi@iauyazd.ac.ir</email>
	<code>100319475328460011461</code>
	<orcid>100319475328460011461</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical Engineering, Yazd Branch, Islamic Azad University</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- واحد یزد- دانشگاه آزاد اسلامی</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyyed Amin</first_name>
	<middle_name></middle_name>
	<last_name>Saeid</last_name>
	<suffix></suffix>
	<first_name_fa>سیدامین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سعید</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Saied1696@gmail.com</email>
	<code>100319475328460011462</code>
	<orcid>100319475328460011462</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical Engineering, Yazd Branch, Islamic Azad University</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- واحد یزد- دانشگاه آزاد اسلامی</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
