<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Association of Electrical and Electronics Engineers</title>
<title_fa>نشریه مهندسی برق و الکترونیک ایران</title_fa>
<short_title>Journal of Iranian Association of Electrical and Electronics Engineers</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jiaeee.com</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2676-5810</journal_id_issn>
<journal_id_issn_online>2676-6086</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61882/jiaeee</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>20</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارا ئه طرح  جدیدی برای حفاظت ریزشبکه AC مبتنی بر زاویه فاز تفاضلی مولفه تحمیلی خطای جریان</title_fa>
	<title>A Novel Scheme for AC Microgrid Protection Based on Differential Phase Angle of Fault Component Current</title>
	<subject_fa>قدرت</subject_fa>
	<subject>Power</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;span dir=&quot;RTL&quot;&gt;ریزشبکه&amp;shy; ها برای مدیریت فنی و اقتصادی نفوذ منابع تولید پراکنده&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt; در شبکه &amp;shy;های&amp;shy; توزیع طی دهه اخیر مطرح شده &amp;shy;اند. ارائه یک طرح حفاظتی اولیه با امنیت و قابلیت اعتماد مناسب برای ریزشبکه&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;shy;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt; های جریان متناوب به دلیل استفاده از انواع تکنولوژی&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;shy;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;های تولید پراکنده یک مساله چالش برانگیز است. در این مقاله یک طرح حفاظتی جدید و مستقل با استفاده از اندازه&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;shy;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;گیری&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;shy;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;های فازور سنکرون جریان به دست آمده از باس&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;shy;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;های ریزشبکه برای تشخیص انواع خطاهای اتصال کوتاه داخلی از خارجی در مکان&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;shy;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;های مختلف ارائه می&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;shy;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;شود. عملکرد طرح حفاظتی پیشنهادی در شرایط بهره&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;shy;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;برداری مختلف ریزشبکه (در حالت اتصال و انفصال از شبکه) و با ورود و خروج &lt;/span&gt;&lt;strong&gt;DG&lt;/strong&gt;&lt;span dir=&quot;RTL&quot;&gt;ها و تغییر سطح نفوذ آن ها مورد ارزیابی قرار می&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;shy;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;گیرد. در این راستا شاخص جدیدی مبتنی بر زاویه فاز تفاضلی مولفه&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;shy;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;های تحمیلی خطای جریان اندازه&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&amp;shy;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;گیری شده از دو باس ریزشبکه برای تشخیص خطاهای اتصال کوتاه از شرایط غیرخطا ارائه می&amp;shy;گردد. عمکرد شاخص پیشنهادی روی سیستم 15 باسه استاندارد به ازای شرایط مختلفی نظیر خطاهای با مقاومت بالا و تغییر سطح نفوذ منابع تولید پراکنده درحالت اتصال و انفصال ریزشبکه ارزیابی می&amp;shy; شود. نتایج به دست آمده نشانگر توانمندی و برتری طرح پیشنهادی در حفاظت مطمئن ریزشبکه می&lt;/span&gt; &lt;span dir=&quot;RTL&quot;&gt;باشد&lt;/span&gt;</abstract_fa>
	<abstract>In the last decades, microgrids have been developed for the techno-economic management of distributed generation (DG) penetration in distribution networks. Providing a primary secure and dependable protection scheme for AC microgrids is a challenging task due to the use of a variety of DG technologies. In this paper, a new independent protection scheme using current synchrophasor measurements obtained from microgrid buses is presented to detect the different kind of internal and external faults in different location. The performance of the proposed protection scheme is evaluated under different operating conditions of the microgrid (in the grid connected and islanded mode) by entering and disconnecting the DGs and changing their penetration level.&amp;nbsp; In this regards, a novel index based on differential phase angle of fault component current obtained from both ends measurements of microgrid buses is proposed to distinguish the fault condition from no-fault situations. The proposed protection index is tested on standard 15-bus microgrid considering high resistance faults and variation in DG penetration in the grid connected and islanded mode. The obtained results indicate the capability and superiority of the proposed approach in reliable microgrid protection</abstract>
	<keyword_fa>ریزشبکه AC,حفاظت,اندازه گیری های فازور سنکرون,منابع تولید پراکنده,مولفه های تحمیلی خطا.</keyword_fa>
	<keyword>AC Microgrid, Protection, Synchrophasor Measurement, Distributed Generation, Fault Component</keyword>
	<start_page>131</start_page>
	<end_page>142</end_page>
	<web_url>http://jiaeee.com/browse.php?a_code=A-10-2492-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>sasan</first_name>
	<middle_name></middle_name>
	<last_name>aliloo</last_name>
	<suffix></suffix>
	<first_name_fa>ساسان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علیلو</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sasan_aliloo@yahoo.com</email>
	<code>100319475328460010379</code>
	<orcid>100319475328460010379</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Urmia University</affiliation>
	<affiliation_fa>دانشکده مهندسی برق و کامپیوتر- دانشگاه ارومیه</affiliation_fa>
	 </author>


	<author>
	<first_name>Tohid</first_name>
	<middle_name></middle_name>
	<last_name>Ghanizadeh Bolandi</last_name>
	<suffix></suffix>
	<first_name_fa>توحید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>غنی زاده بلندی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>t.ghanizadehbolandi@urmia.ac.ir</email>
	<code>100319475328460010380</code>
	<orcid>100319475328460010380</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Urmia University</affiliation>
	<affiliation_fa>دانشکده مهندسی برق و کامپیوتر- دانشگاه ارومیه</affiliation_fa>
	 </author>


	<author>
	<first_name>Daryoush</first_name>
	<middle_name></middle_name>
	<last_name>Nazarpour Akbari</last_name>
	<suffix></suffix>
	<first_name_fa>داریوش</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نظرپور اکبری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>d.nazarpour@urmia.ac.ir</email>
	<code>100319475328460010381</code>
	<orcid>100319475328460010381</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Urmia University</affiliation>
	<affiliation_fa>دانشکده مهندسی برق و کامپیوتر- دانشگاه ارومیه</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
