<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Association of Electrical and Electronics Engineers</title>
<title_fa>نشریه مهندسی برق و الکترونیک ایران</title_fa>
<short_title>Journal of Iranian Association of Electrical and Electronics Engineers</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jiaeee.com</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2676-5810</journal_id_issn>
<journal_id_issn_online>2676-6086</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61882/jiaeee</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>20</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارائه یک راه‌کار ترکیبی مبتنی بر استفاده هم‌زمان از حلقه‌های نانوکریستالی و کابل XLPE جهت کاهش اضافه ولتاژهای گذرای بسیار سریع در پست‌های فشارقوی گازی</title_fa>
	<title>A Hybrid Method Based on The Simultaneous Use of Nanocrystalline Rings and XLPE Cables to Reduce Very Fast Transient Overvoltages in High Voltage Gas Insulation Substations</title>
	<subject_fa>قدرت</subject_fa>
	<subject>Power</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;strong&gt;استفاده از پست&#8204;های ﺑﺎ ﻋﺎﻳﻖ ﮔﺎز&lt;/strong&gt; &lt;strong&gt;در سطوح ولتاژ بالا سیستم&#8204;های قدرت به خاطر مزیت&#8204;های متعدد آن از قبیل نیاز به فضای کمتر، مقاومت در برابر آلودگی&#8204;های محیطی، قابلیت اطمینان بالا و عدم نیاز به تعمیر و نگهداری متوالی در حال گسترش است. یکی از پدیده&#8204;هایی که فواصل عایقی داخل محفظه بسته را در این پست&#8204;ها تهدید می&#8204;کند وقوع اضافه ولتاژهای گذرای بسیار سریع&lt;/strong&gt; &lt;strong&gt;می&#8204;باشد. این اضافه ولتاژها در اثر عملکرد کلیدزنی درپست&#8204;های با عایق گاز برای تجهیزات داخل پست و متصل به آن خطرناک بوده و در صورت تکرار می&#8204;تواند به عایق&#8204; داخلی تجهیزات آسیب برساند. همچنین این اضافه ولتاژهای گذرا در موارد خاص چون ولتاژهای فوق&#8204;العاده بالا ممکن است آسیب&#8204;های جدی را به تجهیزات گران&#8204;قیمت پست وارد نماید. از این رو در این مقاله ضمن بررسی روش&#8204;های موجود جهت محدود نمودن اضافه ولتاژهای گذرای بسیار سریع در نقاط مختلف و حساس پست&#8204;های &lt;/strong&gt;&lt;span dir=&quot;LTR&quot;&gt;GIS&lt;/span&gt;&lt;strong&gt;، یک روش ترکیبی جدید مبتنی بر استفاده هم&#8204;زمان از حلقه&#8204;های نانو کریستالی در باسبار و دو مسیر کابل &lt;/strong&gt;&lt;span dir=&quot;LTR&quot;&gt;XLPE&lt;/span&gt;&lt;strong&gt; جهت اتصال ترانسفورماتور قدرت به پست ارائه شده است. نتایج شبیه&#8204;سازی در سمت 230 کیلوولت پست &lt;/strong&gt;&lt;span dir=&quot;LTR&quot;&gt;GIS&lt;/span&gt;&lt;strong&gt; دانشگاه شیراز نشان می&#8204;دهد که در صورت کلیدزنی در نقاط مختلف، روش پیشنهادی در این مقاله نسبت به سایر روش&#8204;ها دارای کمترین دامنه اضافه ولتاژها می&#8204;باشد. با استفاده از روش ترکیبی پیشنهادی، دامنه اضافه ولتاژهای گذرای بسیار سریع در پایانه ترانسفورماتور قدرت شبکه تحت مطالعه به میزان 7/59 درصد کاهش یافته و این کاهش در دیگر نقاط پست نیز قابل&#8204; مشاهده است.&lt;/strong&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;/span&gt;</abstract_fa>
	<abstract>Use of Gas Insulated Substations (GISs) at high voltage power systems is expanding due to their advantages such as: less required space, resistance to environmental pollutions, high reliability and no need for continuous maintenance. One of the phenomena that threatens the insulation distances inside the closed enclosure in these substations is the occurrence of Very Fast Transient Overvoltages&lt;sup&gt;2&lt;/sup&gt; (VFTOs). These overvoltages that are resulted from switching&lt;sup&gt;3&lt;/sup&gt; operation in the GIS are dangerous for the equipment connected to or inside the GIS and can damage the internal insulation of the equipment. Moreover, these transient overvoltages can cause serious damage to the expensive substation equipment in special cases such as extremely high voltages. In this paper, while reviewing the existing methods to limit VFTO in different sensitive points of the GIS, a new hybrid method is proposed based on the simultaneous use of Nanocrystalline rings in busbars and parallel XLPE&lt;sup&gt;4&lt;/sup&gt; cable path to connect power transformer to the GIS. The simulation results for Shiraz University 230 kV GIS show that in the case of switching operation, the proposed method has the lowest amplitude of overvoltages compared to other methods at different places in this substation. Using the proposed hybrid method, the amplitude of VFTO in the terminal of power transformer of the under-study network is reduced by 59.7% and this reduction can be seen in other points of the substation, as well.&lt;strong&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;/span&gt;&lt;/strong&gt;</abstract>
	<keyword_fa>اضافه ولتاژهای گذرای بسیار سریع, پست‌های فشارقوی گازی,  EMTP-RV</keyword_fa>
	<keyword>Very Fast Transient Overvoltages, High Voltage Gas Insulated Substation, EMTP-RV.</keyword>
	<start_page>171</start_page>
	<end_page>181</end_page>
	<web_url>http://jiaeee.com/browse.php?a_code=A-10-2395-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Hamid Reza</first_name>
	<middle_name></middle_name>
	<last_name>Azizpour</last_name>
	<suffix></suffix>
	<first_name_fa>حمیدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عزیزپور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>H.Re.azizpour@gmail.com</email>
	<code>100319475328460010388</code>
	<orcid>100319475328460010388</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Shahreza Campus, University of Isfahan</affiliation>
	<affiliation_fa>دانشگاه اصفهان - مرکز آموزش عالی شهرضا</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohsen</first_name>
	<middle_name></middle_name>
	<last_name>Jannati</last_name>
	<suffix></suffix>
	<first_name_fa>محسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جنتی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>M.Jannati@shr.ui.ac.ir</email>
	<code>100319475328460010389</code>
	<orcid>100319475328460010389</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Shahreza Campus, University of Isfahan</affiliation>
	<affiliation_fa>دانشگاه اصفهان - مرکز آموزش عالی شهرضا</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Reza</first_name>
	<middle_name></middle_name>
	<last_name>Ansari</last_name>
	<suffix></suffix>
	<first_name_fa>محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>انصاری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>M.R.Ansari@shr.ui.ac.ir</email>
	<code>100319475328460010390</code>
	<orcid>100319475328460010390</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Shahreza Campus, University of Isfahan</affiliation>
	<affiliation_fa>دانشگاه اصفهان - مرکز آموزش عالی شهرضا</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
