<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Association of Electrical and Electronics Engineers</title>
<title_fa>نشریه مهندسی برق و الکترونیک ایران</title_fa>
<short_title>Journal of Iranian Association of Electrical and Electronics Engineers</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jiaeee.com</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2676-5810</journal_id_issn>
<journal_id_issn_online>2676-6086</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61882/jiaeee</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>19</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تشخیص خطا و تکنیک SVPWM تحمل خطای مبدل شش‌فاز ناشی از خطا سوئیچ‌باز</title_fa>
	<title>Fault Diagnosis and Fault-Tolerant SVPWM Technique of Six-phase Converter under Open-Switch Fault</title>
	<subject_fa>قدرت</subject_fa>
	<subject>Power</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>در این مقاله، یک روش جدید تشخیص&#8204; خطای سوئیچ&#8204;باز برای مبدل شش&#8204;فاز &lt;span dir=&quot;LTR&quot;&gt;AC-DC&lt;/span&gt; بر اساس اختلاف بین جریانِ فاز و مرجع مربوطه و مقایسه این اختلاف با مقدار آستانه تطبیقی پیشنهادشده است. روش تشخیص&#8204; خطا پیشنهادی با سیگنال&#8204;های موردنیاز کنترل&#8204;کننده ادغام&#8204;شده است، از همین روی، خطای سوئیچ&#8204;باز بدون هیچ&#8204;گونه تجهیزات اضافی و محاسبات پیچیده تشخیص داده خواهدشد. روش پیشنهادی تحمل خطا از حالت افزونگی بردارهای فضایی در مدولاسیون پهنای پالس بردار فضایی (&lt;span dir=&quot;LTR&quot;&gt;SVPWM&lt;/span&gt;) استفاده نموده&#8204;است و با تغییر سیگنال&#8204;های سوئیچینگ در ناحیه&#8204;های خطادار، مقدار اضافه جریان و مقدار اعوجاج هارمونیک کل (&lt;span dir=&quot;LTR&quot;&gt;THD&lt;/span&gt;) را در فازهای سالم و خطادار کاهش داده&#8204;است. این روش بدون افزودن پایه، سوئیچ یا تریاک (&lt;span dir=&quot;LTR&quot;&gt;TRIAC&lt;/span&gt;)، به مدار انجام شده&#8204;است. درنهایت، روش پیشنهادی تحمل خطا با شبیه&#8204;سازی در محیط سیمولینک نرم&#8204;افزار &lt;span dir=&quot;LTR&quot;&gt;MATLAB&lt;/span&gt; ارزیابی&#8204;شده و نتایج حاصل از این شبیه&#8204;سازی تاثیر آن را نشان می&#8204;دهد.&lt;span dir=&quot;LTR&quot;&gt;&lt;/span&gt;
&lt;div&gt;&lt;div&gt;&lt;/div&gt;&lt;/div&gt;</abstract_fa>
	<abstract>In this paper, a new open-switch fault diagnosis method is proposed for the six-phase AC-DC converter based on the difference between the phase current and the corresponding reference using an adaptive threshold. The open-switch faults are detected without any additional equipment and complicated calculations, since the proposed fault detection method is integrated with the controller required signals. The proposed fault-tolerant technique reduces the value of overcurrent and total harmonic distortion (THD) on the healthy and faulty phases, by considering the redundancy mode of space vectors in space vector pulse width modulation (SVPWM) and changing the switching signals in fault regions. This technique is performed without adding any legs, switches or triode for alternating currents (TRIAC) to the circuit. Finally, the proposed fault-tolerant technique is evaluated by MATLAB simulation and the results show its effectiveness.&lt;strong&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;/span&gt;&lt;/strong&gt;</abstract>
	<keyword_fa>تشخیص خطا, تکنیک SVPWM تحمل خطا, خطای سوئیچ‌باز, مبدل شش‌فاز</keyword_fa>
	<keyword>Fault diagnosis, fault-tolerant SVPWM technique, open-switch fault, six-phase converter.</keyword>
	<start_page>93</start_page>
	<end_page>104</end_page>
	<web_url>http://jiaeee.com/browse.php?a_code=A-10-2427-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Rouhollah</first_name>
	<middle_name></middle_name>
	<last_name>Bolbolnia</last_name>
	<suffix></suffix>
	<first_name_fa>روح اله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بلبل نیا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>R.bolbolnia@email.kntu.ac.ir</email>
	<code>10031947532846009841</code>
	<orcid>10031947532846009841</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical and Computer Engineering, Faculty of Electrical Engineering, K. N. Toosi University of Technology</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- دانشگاه صنعتی خواجه‌نصیرالدین طوسی</affiliation_fa>
	 </author>


	<author>
	<first_name>Karim</first_name>
	<middle_name></middle_name>
	<last_name>Abbaszadeh</last_name>
	<suffix></suffix>
	<first_name_fa>کریم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عباس زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Abbaszadeh@kntu.ac.ir</email>
	<code>10031947532846009842</code>
	<orcid>10031947532846009842</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical and Computer Engineering, Faculty of Electrical Engineering, K. N. Toosi University of Technology</affiliation>
	<affiliation_fa>دانشکده مهندسی برق- دانشگاه صنعتی خواجه‌نصیرالدین طوسی</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
