<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Iranian Association of Electrical and Electronics Engineers</title>
<title_fa>نشریه مهندسی برق و الکترونیک ایران</title_fa>
<short_title>Journal of Iranian Association of Electrical and Electronics Engineers</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jiaeee.com</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2676-5810</journal_id_issn>
<journal_id_issn_online>2676-6086</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.61882/jiaeee</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>19</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>طراحی سیستم کنترل و تحلیل عملکرد گذر از خطای سیستم تولید  میکروتوربین متصل به شبکه</title_fa>
	<title>Control System Design and Fault-Ride-through Performance Analysis of Grid-Connected Microturbine Generation System</title>
	<subject_fa>قدرت</subject_fa>
	<subject>Power</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>میکروتوربین ها بعنوان یکی از منابع تولید پراکنده، در سال های اخیر بسیار مورد استفاده قرار گرفته اند. در این مقاله به بررسی نحوه ی کنترل یک میکروتوربین و تحلیل عملکرد آن در حالت متصل به شبکه پرداخته می شود. در این راستا ابتدا ساختار و مدل مکانیکی میکروتوربین بررسی می شود. سپس ساختار الکتریکی میکروتوربین که شامل یک ژنراتور سنکرون مغناطیس دائم و مبدل های الکترونیک قدرت است، معرفی می شود. در این پژوهش، مبدل های الکترونیک قدرت واسط بین ژنراتور و لینک &lt;span dir=&quot;LTR&quot;&gt;DC&lt;/span&gt; شامل ترکیب یک یکسوساز پل سه فاز دیودی و مبدل باک است که به عنوان مبدل سمت ژنراتور شناخته می&amp;nbsp;شوند. همچنین بین لینک &lt;span dir=&quot;LTR&quot;&gt;DC&lt;/span&gt; و شبکه، یک اینورترسه فاز منبع ولتاژ قرار گرفته که مبدل سمت شبکه نامیده می شود. به عنوان نوآوری، دو روش کنترلی برای مبدل های سمت ژنراتور و شبکه تعریف و سپس ساختار کنترلی مبدل ها در این دو روش ارائه &amp;nbsp;می گردد. نتایج حاصل از شبیه سازی سیستم تحت مطالعه در محیط &lt;span dir=&quot;LTR&quot;&gt;Simulink/MATLAB&lt;/span&gt; نشان می&amp;nbsp;دهد که در روش کنترلی اول، ولتاژ خازن لینک &lt;span dir=&quot;LTR&quot;&gt;DC&lt;/span&gt; در حین خطای شبکه بطور ناگهانی افزایش یافته و به 3/5 برابر ولتاژ نامی می رسد، در صورتی که در روش کنترلی دوم، ولتاژ خازن به 1/2 مقدار نامی در حین خطا می رسد. بنابراین، روش دوم کنترلی که مبتنی بر کنترل ولتاژ باس &lt;span dir=&quot;LTR&quot;&gt;DC&lt;/span&gt; توسط مبدل سمت ژنراتور و کنترل توان اکتیو &amp;nbsp;و راکتیو تزریقی به شبکه به وسیله مبدل سمت شبکه است، از نظر قابلیت عبور از خطا عملکرد بهتری دارد.&lt;br&gt;
&amp;nbsp;</abstract_fa>
	<abstract>In recent years, microturbines as one the distributed generation sources have widly used. This paper investigates the control structure of the microturbine and analyzes its performance in grid-connected mode. In this way, first, the mechanical model of the microturbine is presented. Then, the electrical structure of the microturbine, consisting&amp;nbsp; of permanent magnet synchronous generator (PMSG) and power electronics converters (PECs), is introduced. The PECs placed between the PMSG and DC-link are known as the generator-side converter and includes a three-phase diode rectifier and a buck converter. Also, a three-phase voltage source inverter (VSI) is employed between the DC-link and grid as the grid-side converter. As the paper novelty, two control approaches for the generator- and grid-side converters are defined, and then control structures of the converters are presented. Simulation results of the study system in the Simulink/MATLAB environment show that the in the first control approach the DC link voltage reaches a value 3.5 times the nominal value during the fault, while the peak value of the DC link voltage with the esecond control approach is 1.2 times the nominal value during the fault. Hence, the second control approach, in which the generator-side converter controls the DC bus voltage and the grid-side converter regulates the injected active and reactive powers, is better in terms of fault-ride-through performance.</abstract>
	<keyword_fa>سیستم تولید میکروتوربین, مبدل های سمت ژنراتور و سمت شبکه, مدل متوسط مبدل باک, اینورتر منبع ولتاژ متصل به شبکه, قابلیت گذر از خطا</keyword_fa>
	<keyword>Microturbine generation system, generator-side and grid-side converters, average model of buck converter, grid-connected voltage source inverter, fault-ride-through ability</keyword>
	<start_page>139</start_page>
	<end_page>152</end_page>
	<web_url>http://jiaeee.com/browse.php?a_code=A-10-1853-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Allahyar </first_name>
	<middle_name></middle_name>
	<last_name>Akhbari </last_name>
	<suffix></suffix>
	<first_name_fa>اللهیار</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اخباری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>allahyar_akhbari@yahoo.com</email>
	<code>10031947532846009849</code>
	<orcid>10031947532846009849</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical and Computer Engineering, University of Kashan</affiliation>
	<affiliation_fa>دانشکده مهندسی برق و کامپیوتر- دانشگاه کاشان</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohsen</first_name>
	<middle_name></middle_name>
	<last_name>Rahimi</last_name>
	<suffix></suffix>
	<first_name_fa>محسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رحیمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mrahimi@kashanu.ac.ir</email>
	<code>10031947532846009850</code>
	<orcid>10031947532846009850</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Electrical and Computer Engineering, University of Kashan</affiliation>
	<affiliation_fa>دانشکده مهندسی برق و کامپیوتر- دانشگاه کاشان</affiliation_fa>
	 </author>


	<author>
	<first_name>Ahmad Reza </first_name>
	<middle_name></middle_name>
	<last_name>Atapoor </last_name>
	<suffix></suffix>
	<first_name_fa>احمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عطاپور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ra_atapoor@yahoo.com</email>
	<code>10031947532846009851</code>
	<orcid>10031947532846009851</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Electrical and Computer Engineering, University of Kashan</affiliation>
	<affiliation_fa>دانشکده مهندسی برق و کامپیوتر- دانشگاه کاشان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
